What we check
- A visual check of the switchboard: no damaged or fused equipment or cables, and nothing without proper insulation.
- The current rating and breaking capacity of each protective device suits the circuit it protects.
- Any re-wireable fuses haven't deteriorated from arcing and have no exposed live parts.
- Every switch and protective device is clearly labelled with the circuit it controls.
- The main switch has overload and short circuit protection.
- All neutral bars sit on insulated fittings.
- Earth conductors are on the earth bar and neutral conductors are on the neutral bar.
- The main earthing conductor is the right size, is properly connected at the main switchboard, and the earth electrode meets current standards.
- The MEN connection between neutral and earth at the main switchboard.
- The switchboard is built and installed for fire containment.
- All power and light circuits have safety switches.
- Every safety switch is tested for trip time with calibrated instruments.
- A visual inspection of power points, switches and light fittings.
What you get at the end
A detailed report to keep on file, with photos of anything we found. It sets out what's up to standard and what isn't. You'll also get a written quote with our recommendations for fixing any defects, so you know the cost before you decide anything.